EMA Resources

Blog

Home > EMA Resources > Blog > Tutorial: Appendix A – Creating Directed Groups

Tutorial: Appendix A – Creating Directed Groups

By using Directed Groups, you can prioritize issues in your design. Creating Directed Groups allows you to select an entire interface based on component connectivity rather than net name.
 

Step 1: Set the Analysis Mode to “Directed Groups” and click Select Directed Groups in the Workflow Manager.

This will bring up the dialog box to select, create or modify directed groups.

Note: The following information is included in the Directed Group Selection Dialog Box:
  • Directed Group Selection: Lists the selected directed groups-the portion of a net between a starting component and ending component(s).
  • Create Directed Group: Contains an expandable section to create directed groups by selecting the Start and End Component(s).
  • Directed Group Creation Preview: Allows you to see a preview of the created directed group and select the desired nets.

 

 
Step 2: Create a Directed Group.

Select a starting component from the list in the Start Component box. This will automatically create a list of the valid ending components in the End Component box.

Select an ending component from the list in the End Component box.

Note: For boards with many components, filters are available to help find the desired components. Filter by pin count or component name. You also have the option to hide passive components (Resistors, Capacitors and Inductors).


 

Step 3: Preview and Create the Directed Group.

Select the desired nets in the Directed Group Creation Preview Window. By default, all nets are selected.

Note: You can filter by type of net (Single Ended or Differential) as well as topology (point-to-point or multi-drop) to find the desired nets.
 

When the desired nets have been selected, click Create. The Directed Group is created and can be viewed in the Directed Group Selection Window.

Note: By default, the created directed group is automatically selected for analysis.

Click Apply and click OK.


 

Step 4: Continue with the Analysis.

Click Start Analysis in the Workflow Manager.
 


 

Step 5:  View the results for the Directed Group. 

Under View Modes select “Directed Group”.

Note: This will generate the Impedance Plot or Coupling Plot (based on which analysis you are performing). It is important to note that this view is only available when performing analysis on Directed Groups.


 

Step 6: Click on the plot to view the results.

View specific nets by using the selection window on the left or view simulation results for all nets in the directed group. By default, all nets are selected.

Note: There are two views available in the plot:
  • Bar/Expandable: Double-clicking on a portion of a net in the Bar Graph will bring you to the location on the PCB. 


     

  • Scatter/Collapsed: Displays a global view which can be used to easily identify outliers.

    Video Tutorial

     

LinkedIn
Email
Get Content Like This Delivered Directly to Your Inbox

Related Resources